Easter Special Sale - Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 575363r9

Welcome To DumpsPedia

210-010 Sample Questions Answers

Questions 4

How many EMC ESRS servers are deployed with a Vblock System 320 mini Advanced Management Pod (mini-AMP)?

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 5

EMC Secure Remote Support (ESRS) is deployed in the Advanced Management Pod (AMP).

Which three hardware components are monitored by this call home software? (Choose three.)

Options:

A.

EMC VNXe

B.

Cisco MDS 9148 switch

C.

Cisco Nexus 1000V switch

D.

EMC VMAX

E.

Cisco Catalyst 3650 switch

Buy Now
Questions 6

In a Vblock System 720, what is the maximum standard LUN size on an EMC Symmetrix VMAX 10K/20K/40K?

Options:

A.

20 GB

B.

64 GB

C.

240 GB

D.

2,457 GB

Buy Now
Questions 7

What is the hot spare drive requirement for a Vblock System 320 storage array?

Options:

A.

Hot spare drives must exist for every 100 drives of any type drive in the array.

B.

Hot spare drives must exist for every 100 drives of the same type drive in the array.

C.

Hot spare drives must exist for every 30 drives of the same type drive in the array.

D.

Hot spare drives must exist for every 30 drives of any type drive in the array.

Buy Now
Questions 8

What is a valid method to install EMC PowerPath/VE onto a VMware ESXi host?

Options:

A.

Install using vCenter Update Manager (VUM).

B.

Install from the PowerPath/VE vCenter plug-in.

C.

Install remotely from the array management server.

D.

Install using the rpowermt command.

Buy Now
Questions 9

Which RAID type is used for the Cisco UCS C220 servers in a Vblock System 320 Advanced Management Pod (AMP)?

Options:

A.

RAID 0

B.

RAID 1

C.

RAID 5

D.

RAID 6

Buy Now
Questions 10

Where does a system administrator configure virtual machine affinity rules in VMware vCenter?

Options:

A.

HA settings

B.

DPM settings

C.

virtual machine settings

D.

DRS settings

Buy Now
Questions 11

You are required to setup the network interface on a Vblock System 320 storage array, which is used for file level access.

In which mode should the interface be configured?

Options:

A.

fail safe networking

B.

link aggregation

C.

Ethernet channel

D.

network trunking

Buy Now
Questions 12

Customers provide the information used to develop the Logical Configuration Survey (LCS) before manufacturing begins.

What information is required? (Choose two.)

Options:

A.

syslog server IP address

B.

NTP server IP address

C.

method of device access (telnet or SSH)

D.

MIB browser IP address

Buy Now
Questions 13

Which Vblock System 320 component provides Fibre Channel network connectivity in a unified network architecture?

Options:

A.

Cisco MDS 9148

B.

Cisco Nexus 5548UP

C.

Cisco Nexus 1000V

D.

Cisco Catalyst 3750

Buy Now
Questions 14

You are adding a new VLAN from the Cisco Nexus 1000V. You use the state enabled command.

What is the result of this command?

Options:

A.

It creates a new VLAN in the Cisco Nexus 1000V.

B.

It creates a new VMkernel port in the ESXi host.

C.

It creates a new VLAN in the Cisco fabric interconnects.

D.

It creates a port group in the vCenter server.

Buy Now
Questions 15

In Cisco UCSM, which policy allows you to enable the Cisco Discovery Protocol (CDP)?

Options:

A.

Adapter Policy

B.

Dynamic vNIC Connection Policy

C.

QoS Policy

D.

Network Control Policy

Buy Now
Questions 16

How many on-board unified ports does the Cisco Unified Computing System (UCS) 6296UP fabric interconnect provide?

Options:

A.

48

B.

62

C.

96

D.

97

Buy Now
Questions 17

Which EMC software is required to upgrade code on a Vblock System 200 storage array?

Options:

A.

Unisphere Service Manager

B.

Unisphere Server Utility

C.

VNX Installation Assistant

D.

Unisphere Client

Buy Now
Questions 18

You are required to log in to a Cisco UCS C220 CIMC to validate the firmware.

What are two ways to launch and obtain the login prompt? (Choose two.)

Buy Now
Questions 19

What are three components of the Cisco UCS system that make up the Vblock System 320 compute layer? (Choose three.)

Options:

A.

X-Blade Data Movers

B.

fabric interconnect

C.

Cisco Nexus switch

D.

fabric extenders

E.

chassis

Buy Now
Questions 20

You are backing up a Cisco UCS configuration.

Which parameter should you select to retain assigned vHBAs, WWPNs, vNICs MACs, WWNNs, and UUIDs?

Options:

A.

Retain Identities

B.

Preserve Identities

C.

Include Identities

D.

Copy Identities

Buy Now
Questions 21

-- Exhibit --

-- Exhibit --

Click the Exhibit button.

Vblock Systems have multiple power connector capabilities.

Which power receptacle is shown in the exhibit?

Options:

A.

30A 250V, 3 phase (NEMA L15-30P)

B.

60A 250V,3 phase (IEC 60309)

C.

60A 120V, 3 phase (IEC 60309)

D.

30A 120V, 3 phase (C8303 L6-30P)

Buy Now
Questions 22

What is a reason to use EMC Powerpath/VE on a Vblock System 720?

Options:

A.

to provision storage from the vCenter client

B.

to optimize load balancing on the storage fabric

C.

to add additional vStorage APIs for Array Integration (VAAI) features

D.

to optimize storage caching features on the ESXi host

Buy Now
Questions 23

What are three possible results when enabling vSphere High Availability (HA)? (Choose three.)

Options:

A.

Virtual machines will migrate from one host to another as resource availability changes.

B.

An ESXi host fails and some of the virtual machines restart on other hosts in the cluster.

C.

A virtual machine fails and automatically restarts on another host in the cluster.

D.

VMware vSphere Fault Tolerance will be enabled.

E.

A virtual machine is unable to boot due to limited cluster resources.

Buy Now
Questions 24

On the Vblock System 720, which two workload types require separate disk groups? (Choose two.)

Options:

A.

RecoverPoint

B.

bare metal blades

C.

Oracle

D.

SAP

Buy Now
Questions 25

You are assigned to deploy a new host in a Vblock System, with block storage attached.

Which type of zoning would be performed on the Cisco 9148 switch to accomplish this task?

Options:

A.

port zoning

B.

WWPN zoning

C.

symbolic node name zoning

D.

WWNN zoning

Buy Now
Questions 26

On a Vblock System 320, each VMware ESXi host will boot from a SAN-attached boot drive presented from the EMC VNX array.

Which statement is true according to VCE standards for boot LUNs?

Options:

A.

Use Fibre Channel drives to create a RAID group, use RAID-5 4+1 RAID group, then create a 20 GB LUN.

B.

Use Fibre Channel drives to create a RAID group, use RAID-5 7+1 RAID group, then create a 20 GB LUN.

C.

Use SAS drives to create a RAID group, use RAID-5 4+1 RAID group, then create a 20 MB LUN.

D.

Use SAS drives to create a RAID group, use RAID-5 4+1 RAID group, then create a 20 GB LUN.

Buy Now
Questions 27

After the installing the Cisco Nexus 1000V, the administrator uses the command show svs connections.

This command shows the connection status of which component?

Options:

A.

ESXi host

B.

vCenter server

C.

Secondary Virtual Supervisor Module

D.

VMware Update Manager (VUM)

Buy Now
Questions 28

When performing hardware maintenance on a Cisco UCS B-Series blade, which GUI parameter should be selected before removing the blade out of the chassis?

Options:

A.

Remove

B.

Re-acknowledge

C.

Decommission

D.

Diagnostic Interrupt

Buy Now
Questions 29

You observe that a host in a high availability (HA) cluster shows as disconnected within vCenter. The virtual machines running on the disconnected host have not automatically restarted as expected.

What is the cause of this problem?

Options:

A.

NTP was not configured on the HA cluster.

B.

vMotion is not enabled on the cluster hosts.

C.

The disconnected host was the master host.

D.

The host is still exchanging a data store heartbeat.

Buy Now
Questions 30

Which Cisco management software is required to setup EMC e-mail home for Cisco MDS switches?

Options:

A.

Cisco Data Center Network Manager (Cisco DCNM-SAN)

B.

Cisco Unified Computing System Manager (Cisco UCSM)

C.

Cisco Smart Call Home (Cisco SCH)

D.

Cisco Terminal Access Controller Access Control System (Cisco TACACS)

Buy Now
Questions 31

Which Cisco switch provides IP connectivity for the Vblock System 320?

Options:

A.

Cisco Nexus 5548UP

B.

Cisco Catalyst 3750-X

C.

Cisco MDS 9148

D.

Cisco Nexus 2248TP

Buy Now
Questions 32

Which two virtual machines are deployed as part of the Advanced Management Pod (AMP)? (Choose two.)

Options:

A.

VMware View Connection server

B.

VMware Update Manager server

C.

Cisco Adaptive Security Appliance

D.

VMware vCenter server

Buy Now
Questions 33

A customer uses EMC's Unified Infrastructure Manager (UIM) to deploy a Vblock System.

Which two post-deployment steps must the engineer take within Unified Computing System Manager (UCSM) to provide a VCE best-practice configuration? (Choose two.)

Options:

A.

Set the Fibre Channel QoS policy in service profiles.

B.

Set the host firmware package in service profiles.

C.

Associate the service profiles to blades

D.

Set enable failover for vNICs in service profiles.

Buy Now
Questions 34

At which link speed do the fabric extenders (FEX) within the Cisco UCS chassis connect to Cisco fabric interconnects?

Options:

A.

2 GbE

B.

4 GbE

C.

8 GbE

D.

10 GbE

Buy Now
Questions 35

In Cisco Unified Computing System Manager (UCSM), which selection under the Admin tab would you select to configure SNMP?

Options:

A.

Call Home

B.

Communication Services

C.

Management Interfaces

D.

Syslog

Buy Now
Questions 36

During a Vblock System logical build, which two management components within Unified Computing System Manager (UCSM) require configuration with an IP address? (Choose two.)

Options:

A.

fabric extender

B.

fabric interconnect

C.

UCSM

D.

Cisco Nexus 5108 chassis

Buy Now
Questions 37

What are three core VMware components of a Vblock System? (Choose three.)

Options:

A.

vCenter server

B.

Update Manager

C.

ESRS

D.

ESX

E.

ESXi

Buy Now
Questions 38

Which port is used for communication between EMC Secure Remote Support (ESRS) and the Policy Manager?

Options:

A.

443

B.

5414

C.

8090

D.

8443

Buy Now
Exam Code: 210-010
Exam Name: VCE Vblock™ Systems Deployment and Implementation - Core Exam
Last Update: May 15, 2024
Questions: 128
$64  $159.99
$48  $119.99
$40  $99.99
buy now 210-010