Winter Special Sale - Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 575363r9

Welcome To DumpsPedia

H13-624_V5.5 Sample Questions Answers

Questions 4

During routine O&M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?

Options:

A.

If the new device time is later than the deadline for saving historical performance data, the system will no longer save historical performance data.

B.

Changing the device time will affect the life spans of disks and controllers, which may trigger alarms indicating that the hardware life span expires or hardware is aging.

C.

If the new system time is later than the user-defined password expiration date, the system may force the user to change the login password.

D.

If the new device time is later than the certificate validity period, the certificate will expire.

Buy Now
Questions 5

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O&M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Buy Now
Questions 6

Cache policies and configurations are involved in storage-layer performance optimization of Huawei flash storage. Which of the following statements is false about the high and low watermarks of a cache?

Options:

A.

Generally, the low watermark for storing dirty data in the cache should not be too low. The recommended value is 20%.

B.

Generally, the high watermark of the cache should not be too high, and the difference between the high and low watermarks should not be too small.

C.

If the high watermark of the cache is too high, I/O fluctuation and latency increase will occur usually when the current I/O traffic bursts.

D.

If the high watermark of the cache is too high, the write performance will be affected. If the low watermark of the cache is too low, the read performance will be affected.

Buy Now
Questions 7

Assume a government office purchases several Huawei OceanStor Pacific series storage products. Which statement is false about the hardware and software deployment of the storage products?

Options:

A.

During software deployment, Device Manager must be used to initialize the network of nodes.

B.

During hardware deployment, SmartKit can be used to install OSs in batches.

C.

During software deployment, SmartKit can be used to configure clusters, such as disabling Link Layer Discovery Protocol (LLDP) for an OS and enabling the function of Baseboard Management Controller (BMC) mobile customization.

D.

SmartKit can be used to configure the BMC IP addresses, subnet masks/prefixes, gateways, and BMC host names, and to check the firmware, OS, and driver versions.

Buy Now
Questions 8

When demarcating a performance issue of Huawei flash storage, engineer A finds that the latency observed on the compute side is much longer than that on the storage side. This indicates that the issue most possibly occurred on the storage, for example, the disk performance upper limit has been reached.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 9

Assume an Industry customer purchased a Huawel flash storage device for service deployment. After a fault occurs, an engineer needs to use the CLI to view bit error Information of front end host ports for troubleshooting. Which of the following commands cannot be used for this purpose?

Options:

A.

show coexist-forward-switch

B.

show controller io io_type=frontEnd controller_id=XX

C.

show port biLerror

D.

show host-port error

Buy Now
Questions 10

In Huawei all flash storage, the_____feature can automatically store data in different locations based on specified rules for intelligent data management.

Options:

Buy Now
Questions 11

A government customer has purchased two Huawei flash storage devices and deployed them in different data centers for running remote replication services. When a primary/secondary switchover is performed for the remote replication pair, the primary and secondary sites record the data changes. When the secondary site becomes the primary site following the primary/secondary switchover, all data will be synchronized between the primary and secondary sites.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 12

When delivering a flash storage project, Huawei engineers introduced the multi-tenant feature of flash storage to the customer. This feature isolates service data. Although different tenants cannot access each other’s LUNs, they can access each other’s file system.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 13

When delivering a Huawel OceanStor Pacific scale-out storage project, Huawei engineers Introduced the end-to-end load balancing capabllty supported by the scale-out storage to the customer. Which of the following statements are false about the load balancing capability?

Options:

A.

The route-based hash policy of the persistence layer is different from that of the service layer. The route-based hash policy of the persistence layer is implemented based on weights, while that of the service layer is implemented based on STORE DHT.

B.

Unstructured and structured services at the service layer have different route-based hash policies. However, both unstructured and structured services are mapped based on the same basic routing model.

C.

In load balancing at the semantic layer, a directory is divided into 256 partitions by default and can be adjusted to a maximum of 512 partitions.

D.

Routes at the service layer balance storage space and accelerate fault reconstruction.

Buy Now
Questions 14

A government customer has purchased several Huawei OceanStor Dorado 18000 series storage devices for service deployment, and an engineer needs to create storage pools on the storage system. However, before doing so, the engineer must configure LUNs and LUN groups, and create the mapping between the LUN groups and host groups.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 15

Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?

Options:

A.

During the configuration, the engineer needs to configure the SNMP protocol and USM users in the storage system for receiving and querying system alarms.

B.

To view the display format of Syslog content, the engineer can run the "show notification syslog" command.

C.

To change the display format of Syslog content to CEF, the engineer can run the "change syslog-notification format_type=cef" command.

D.

If certificates and CA certificates are generated on the Syslog server, the engineer does not need to perform any operation in the storage system.

Buy Now
Questions 16

Similar to the alarm analysis method, the replacement method can be used to locate and rectify any type of faults for Huawei converged storage, and has no special requirement for maintenance personnel.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 17

An engineer wants to configure the iSCSI block service on a Huawei scale-out storage device. Which of the following operations must be performed by the engineer?

Options:

A.

Create a block storage pool.

B.

Configure the iSCSI service.

C.

Configure DPC share access on a client.

D.

Install DPC.

Buy Now
Questions 18

When delivering a Huawei flash storage project, an engineer introduced the SAN/NAS Integrated architecture to the customer. Which of the following statements Is false about the architecture?

Options:

A.

The protocol layer is responsible for protocol parsing and permission management. SAN and NAS are two sets of semantic logic. Therefore, different service entry components are used.

B.

The space management layer uses the active-active high reliability mode to provide reliable data protection capabilities based on actual service scenarios of customers.

C.

The software architecture consists of the following layers from top to bottom: protocol, data service, cache, file and block space management, and storage pool.

D.

At the protocol layer, NFS/CIFS supports direct TCP offload engine (DT06), while ISCSI does not.

Buy Now
Questions 19

A financial customer has purchased several Huawei OceanStor Dorado series storage devices for mission-critical service deployment. SmartMigration is configured to migrate services from a source LUN to a target LUN without interrupting host services. Which of the following statements about this feature is false?

Options:

A.

The implementation of a SmartMigration task between heterogeneous storage systems depends on the LUN takeover function provided by SmartVirtualization.

B.

When configuring this feature, you must plan the capacities of the source and target LUNs. The capacity of the target LUN must be greater than or equal to that of the source LUN.

C.

When configuring this feature, you cannot use a LUN that has been mapped to an application server as the target LUN of a SmartMigration task.

D.

The higher the migration rate, the better the host service performance is. Therefore, the highest migration rate can be used when the host service load is heavy.

Buy Now
Questions 20

Which statements are false about software Installation of Huawei OceanStor Pacific series storage systems?

Options:

A.

To install the Distributed Parallel Client (DPC), the switch configuration is required before the installation regardless of whether the low level design (LLD)- or wizard-based installation mode is selected.

B.

To interconnect with FusionCompute during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

C.

To interconnect with Huawei Cloud Stack during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

D.

To install the file service in the standard protocol scenario, the switch configuration is not required throughout the entire installation process.

Buy Now
Questions 21

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

Options:

A.

During block service installation, if management nodes are deployed where compute and storage nodes are converged, the number of vCPUs on each converged compute and storage node must be greater than or equal to 20.

B.

During block service installation, if converged deployment of storage and compute nodes is required, the difference between the disk quantities on any two nodes in the same storage pool cannot be greater than 2 or 30% of the disk quantity on the node having most disks.

C.

If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.

D.

To install the Distributed Parallel Client (DPC), the memory required for running the DPC software on a compute node must be greater than or equal to 20 GB.

Buy Now
Questions 22

Before configuring services for Huawei flash storage, you need to Initialize the system. Which statement about the initialization is false?

Options:

A.

You must change the IP addresses of the management network port and maintenance network port using the command-line interface (CLt) before applying for and activating a license.

B.

During security configuration management, read-only users have only the access permission to the storage device, that is, they can only perform query operations.

C.

When the TCP+SSl/TLS protocols are used for Syslog alarm notification, you need to set the certificate verification mode to improve the security of storage system logs.

D.

During the wizard-based initialization, you need to configure basic information, such as device information, device time, and licenses.

Buy Now
Questions 23

The LUN active-active balancing feature of Huawei all flash storage Integrates the global load balancing.design. The front-end interface board evenly distributes I/Os to the target controller for load balancing.

Options:

Buy Now
Questions 24

In Huawei backup storage OceanProtect X3000, data reduction supports fixed-length (^duplication by default, but does not support variable-length (^duplication. Therefore, fixed-length ded11plication Is mainly used in the backup field.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 25

The performance of a storage system can be measured by multiple indicators. In application scenarios where the I/O size is greater than or equal to 64 KB, the ________ performance indicator is the main concern for storage performance.

Options:

Buy Now
Questions 26

To analyze disk performance, we can first use tools (such as free, top, vmstat, and pidstat) that support many indicators, and then determine the I/O source and analyze the file system and process I/Os.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 27

A financial customer has purchased a Huawei OceanStor Dorado series storage system for service deployment. To ensure service data reliability, an engineer configures the HyperClone feature on the storage system. Which of the following statements about this feature are false?

Options:

A.

A source LUN and a target LUN form a HyperClone pair, and a source LUN cannot form multiple HyperClone pairs with different target LUNs.

B.

This feature provides a full copy of the source LUN’s data at the synchronization start time. Hosts can read and write the target LUN immediately, without waiting for the copy process to complete.

C.

This feature synchronizes data from the source LUN to the target LUN and can also restore data from the target LUN to the source LUN.

D.

There are significant differences between clone blocks and clone file systems. The former is implemented based on the redirect-on-write (ROW) technology, while the latter is implemented based on the copy-on-write (COW) technology.

Buy Now
Questions 28

Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?

Options:

A.

When a switch network is used, the configured rate of the Fibre Channel host port does not match that of the switch.

B.

The optical fiber is poorly connected or faulty.

C.

The optical module rate of host ports does not match that of front-end storage ports.

D.

The IP address of the service network port on the application server is incorrectly set.

Buy Now
Questions 29

When delivering Huawei all-flash projects, Huawei engineers introduced the HyperCDP feature of flash storage to customers. Which of the following statements are true about this feature?

Options:

A.

Copies created using HyperCDP can be used for data analysis and application testing.

B.

When an application server sends a request to write data to the source LUN after a HyperCDP snapshot is created, the storage system uses the copy-on-write (COW) technology to save the new data to a new location in the storage pool and directs the source LUN’s pointer to the new location.

C.

HyperCDP snapshots cannot be directly mapped to hosts. To read data from a HyperCDP snapshot due to actual service requirements, the administrator needs to share the file system with the host so that the host can read the source file system data at the point in time when the HyperCDP snapshot was created.

D.

HyperCDP is a high-density snapshot and requires the system to construct file system objects. Therefore, the system memory usage is high.

Buy Now
Questions 30

The OceanStor Pacific series storage systems support the _______ feature. This feature uses the classic token bucket algorithm to control the traffic upper limit. If local tokens are insufficient, tokens are continuously generated and added to the token bucket based on the OPS and bandwidth upper limit of the corresponding QoS control object as the rate.

Options:

Buy Now
Questions 31

In actual service scenarios, the HyperMetro feature of Huawei OceanStor Pacific series supports incremental synchronization. If a site fails, the site that wins arbitration continues providing services, and I/O requests change from the dual-write state to the single-write state. After the faulty site recovers, data generated during the fault can be synchronized to the recovered site.

Options:

A.

TRUE

B.

FALSE

Buy Now
Exam Code: H13-624_V5.5
Exam Name: HCIP-Storage V5.5
Last Update: Nov 5, 2025
Questions: 106
$66  $164.99
$50  $124.99
$42  $104.99
buy now H13-624_V5.5