Questions 4

What should be a consideration when having casters (rollers/wheels) or feet under the rack?

Options:

A.

The casters and feet should be larger to avoid a too heavy point load on the floor tile.

B.

Skirts at the bottom of the rack to avoid air flow between the hot and cold aisles.

C.

Casters and feet should be of a soft material, for example rubber, to avoid damage to the raised floor tile.

D.

Casters and feet should not be locked to ensure the racks are still able to be moved to another position.

Buy Now
Questions 5

Which type of Humidifier suspends quartz lamps over an open pool of water?

Options:

A.

Infrared Humidifiers

B.

Water Canister Humidifier

C.

Steam Canister Humidifier

D.

Ultrasonic Humidifier

Buy Now
Questions 6

What is the minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems?

Options:

A.

46 cm / 18 inches

B.

64 cm / 25 inches

C.

60 cm / 24 inches

D.

120 cm / 47 inches

Buy Now
Questions 7

Which is the most damaging type of floor load?

Options:

A.

Concentrated Load / Point Load (CP/ PL)

B.

Uniformly Distributed Load (UDL)

C.

Rolling Load (RL)

D.

All loads are equally damaging to raised floor tiles

Buy Now
Questions 8

Which type of Humidifier rapidly vibrates waster to create a fog or mist?

Options:

A.

Infrared Humidifier

B.

Water Canister Humidifier

C.

Steam Canister Humidifier

D.

Ultrasonic Humidifier

Buy Now
Questions 9

From the list below, which sensor detects smoke the fastest?

Options:

A.

Photoelectric detector

B.

VESDA/HSSD

C.

lonization detector

D.

Sprinkler bulbs

Buy Now
Questions 10

Which design consideration should be implemented with an Inergen-based fire suppression system?

Options:

A.

Install protective covers around the nozzles to avoid accidental gas dumps.

B.

Install the gas containers (tanks) close to the data centre.

C.

To use Inergen only for fires which are not related to electrical power.

D.

Pressure relief valves are required in the room that needs protection.

Buy Now
Questions 11

systems are designed specifically to protect the structure of a building.

Options:

A.

Pro-inert

B.

Inergen

C.

Water sprinkler

D.

Total Flooding

Buy Now
Questions 12

Do I need to check the local standards if I already comply to international standards?

Options:

A.

Local standards do not to be checked as some countries have too many local standards, which will slow down the data centre construction.

B.

You need to check the local standards to ensure compliance to these standards.

C.

Compliance to only international standards is good enough as most local standards are derived from international standards.

D.

Data centres only need to comply to international standards since they are connected to a worldwide international network infrastructure.

Buy Now
Questions 13

Can Electro Magnetic Fields (EMF) cause data centre failures?

Options:

A.

Yes, high levels of EMF can cause data centre failures.

B.

No, only power issues will cause data centre failures.

C.

No, only cooling issues will cause data centre failures.

D.

Yes, but only EMF caused by lightning strikes.

Buy Now
Questions 14

What is a requirement of an FM200 (HFC-227) installation?

Options:

A.

It is a high-pressure gas; therefore nozzles must be mounted with two brackets.

B.

Drainage system under the raised floor.

C.

Install the gas containers (tanks) close to the data centre.

D.

Install pre-action sprinklers in the same room as the FM200.

Buy Now
Questions 15

IP protection grades consist of two numbers.

Which levels of protection do they describe and what is the best protection?

Options:

A.

First digit; protections against the ingress of solid objects. Second digit; protection against ingress of water/fluids. The lower the number the better the level of protection.

B.

First digit; protections against the ingress of solid objects. Second digit; protection against ingress of water/fluids. The higher the number the better the level of protection.

C.

First digit; protections against the ingress of water/fluids. Second digit; protection against ingress of solid objects. The higher the number the better the level of protection.

D.

First digit; protections against the ingress of water/fluids. Second digit; protection against ingress of solid objects. The lower the number the better the level of protection.

Buy Now
Questions 16

Which one of the following does a Physical Infrastructure consists of in a Data Centre?

Options:

A.

Hub

B.

Switch

C.

Rack

D.

Server

Buy Now
Questions 17

The three elements of the fire triangle are,and. (Choose three.)

Options:

A.

Oxygen

B.

Earth

C.

Heat

D.

Water

E.

Fuel

Buy Now
Questions 18

Does shielded twisted pair network cabling provide protection against EMF from power cables?

Options:

A.

Yes, but only if the power cable is placed in a tre-foil cable arrangement.

B.

Yes, as the shielding for twisted pair network cabling is specifically design for low frequency EMF protection.

C.

No, the shielding is designed for alien cross-talk between network cables, it provides no or little protection against low frequency EMF.

D.

No, the shielding for twisted pair network cabling is for physical protection against vandalism and accidental cutting of the cable.

Buy Now
Questions 19

Starting from which Rating does the requirement of Concurrently Maintainability becomes relevant?

Options:

A.

Rated-4

B.

Rated-3

C.

Rated-2

D.

Rated-1

Buy Now
Questions 20

What is the main risk for a data centre when the water supply fails?

Options:

A.

Failure to the water supply could result in IT failure and/or denial of access to operate.

B.

Failure to the water supply could result in DX cooling systems to fail.

C.

Failure to the water supply could cause issues for the cooling of back-up generators.

D.

Failure to the water supply could result in sudden changes of the relative humidity in the Computer room.

Buy Now
Questions 21

is the ability of a system or component to perform its required functions under stated conditions for a specified period of time.

Options:

A.

Scalability

B.

Agility

C.

Reliability

D.

Availability

Buy Now
Questions 22

What is the effect of a high relative humidity in the data centre?

Options:

A.

There is a risk of electrostatic discharge.

B.

In a data centre environment relative humidity is not important, only temperature matters.

C.

There is a risk of not properly functioning of the smoke detectors.

D.

There is a risk of corrosion.

Buy Now
Questions 23

How many monitoring points should be used in Temperature Measurement?

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 24

Which one of the following is an AC Power Quality Anomaly?

Options:

A.

Signal Distortion

B.

Waveform Distortion

C.

Backup Condition

D.

Attenuation

Buy Now
Questions 25

Which one of the following is the last stage in Stages of Combustion?

Options:

A.

Visible Smoke

B.

Intense Heat

C.

Incipient

D.

Flaming Fire

Buy Now
Questions 26

Where should exit/emergency signs be located?

Options:

A.

Depends on the policy of the data centre

B.

At every escape door and pathways leading to doors (arrows)

C.

In the Computer room only

D.

At each door

Buy Now