A solution requested for a use case requires that the scenario is initiated with project updates.
Which Workfront app module will start the scenario immediately?
Which two features or modules can be used to create conditional or nested error handling when using Error Handling Directives? (Choose two.)
Which two actions are best practices for making a Fusion scenario easier to read, share and understand? (Choose two.)
Given the array below, a user wants a comma-separated string of all stat names.
What is the correct expression?
This scenario shows a 1 in the bundle inspector for the Tasks module and a 23 in the bundle inspector for the Project module.
What does the number in the bundle inspector represent?
A Fusion scenario is making too many requests to a third-party API, which returns a 429 "Too Many Requests" error Which technique reduces the number of API requests?
A Fusion user is trying to get a Google Slide presentation to connect to projects in Workfront. Each time the user runs the scenario, this error message appears:
What action should the user take to resolve the error message?
A custom API call to a web service is used inside of a high volume iteration. The module that calls the web service sometimes returns an error - 429: Too many requests.
Which two actions may be used to address this error? (Choose two.)
A Fusion Developer receives frequent notifications that a specific Scenario has been stopped. Upon investigation, the developer notes that there is nothing wrong with the data or process in the scenario, but that the error always occurs on a specific module that calls a third-party system. The error recorded is consistently a service unavailable error, particularly during times of high network traffic to the target system.
Which action should the Fusion Developer take to reduce the number of times the scenario is automatically stopped by Fusion?
Which action makes it possible to see the exact API request and the response a module executes?
A Fusion user is developing a scenario. The first half of the scenario needs to be tested for consistency. No additional actions are to be executed.
Which control module is required to disable the execution of subsequent modules?
A customer wants all their Salesforce Opportunities to sync with their connected projects in Workfront -approximately 20,000+ projects.
After the admin sets a Workfront Fusion scenario to run each night and perform this action, the scenario is run once to test. After 40 minutes, it unexpectedly stops running.
Why did this occur?