Month End Sale - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65percent

Welcome To DumpsPedia

Fire-Inspector-II Sample Questions Answers

Questions 4

Given: In organic coating processes where Class I liquids are exposed to the air, Class I, Division I electrical installations are required to be outside the immediate vicinity of pumps or equipment.

"Immediate vicinity" means in addition to a vertical distance a zone extending from the vapor liberation point __ ft. horizontally in all directions.

Options:

A.

5

B.

10

C.

20

D.

50

Buy Now
Questions 5

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not accessible to the public, is __ lb. water capacity.

Options:

A.

735

B.

1,000

C.

2,000

D.

2,500

Buy Now
Questions 6

Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.

Options:

A.

30

B.

100

C.

200

D.

220

Buy Now
Questions 7

Keys necessary for the unlocking of exit doors must be individually identifiable by both sight and touch in which of the following occupancies?

Options:

A.

Group A occupancies

B.

Group E occupancies

C.

Group I occupancies

D.

Group R occupancies

Buy Now
Questions 8

The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.

Options:

A.

875

B.

1,000

C.

1,313

D.

1,750

Buy Now
Questions 9

A required standpipe shall be installed when the progress of construction above the lowest level of fire department access reaches a maximum of __ ft.

Options:

A.

30

B.

40

C.

55

D.

75

Buy Now
Questions 10

Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.

Options:

A.

55

B.

100

C.

250

D.

500

Buy Now
Questions 11

Pressure tests for organic coating process piping shall be conducted for a minimum of:

Options:

A.

30 minutes

B.

45 minutes

C.

1 hour

D.

2 hours

Buy Now
Questions 12

The minimum working space width for a 66-in. wide electrical equipment panel shall be in

Options:

A.

30

B.

36

C.

66

D.

78

Buy Now
Questions 13

A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds

Options:

A.

225

B.

500

C.

1,000

D.

2,500

Buy Now
Questions 14

Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.

How long must records related to this decision be maintained by the code official?

Options:

A.

Five years

B.

Three years

C.

Until the building is sold

D.

For as long as the building and the condition exist

Buy Now
Questions 15

Hazardous occupancies involved in the manufacturing of organic coatings:

Options:

A.

do not require a fire alarm system.

B.

require only a manual fire alarm system.

C.

require only an automatic fire alarm system.

D.

require both manual and automatic fire alarm systems.

Buy Now
Questions 16

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.

Options:

A.

735

B.

1,000

C.

2,000

D.

2,500

Buy Now
Questions 17

In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?

Options:

A.

5

B.

10

C.

20

D.

30

Buy Now
Questions 18

Exit signs shall have words on the sign in letters ___ inches in height.

Options:

A.

three

B.

four

C.

five

D.

six

Buy Now
Questions 19

What is the occupant load of a 50,000 gross square foot airport terminal concourse?

Options:

A.

200

B.

500

C.

1,000

D.

2,500

Buy Now
Questions 20

Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?

Options:

A.

Type I

B.

Type II

C.

Type III

D.

Type IV

Buy Now
Questions 21

Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?

Options:

A.

They become a public record.

B.

They are time-consuming to complete and file.

C.

They may not address all of the code violations which may be encountered.

D.

They may serve as a basis for legal appeal against the code official's actions.

Buy Now
Questions 22

A local board of appeals may perform all of the following functions except:

Options:

A.

waive requirements of the fire code.

B.

render interpretations of the fire code.

C.

approve alternate materials and types of construction.

D.

adopt rules and regulations for conducting its investigations.

Buy Now
Questions 23

In the fire code, ABS plastics are designated as ___ plastic materials.

Options:

A.

Group A

B.

Group B

C.

Group C

D.

Commodity Class III

Buy Now
Questions 24

Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with

Options:

A.

UL 1975

B.

NFPA 11A

C.

CPSC 16CFR

D.

ASTM D 1784

Buy Now
Questions 25

Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)

Options:

A.

1,500

B.

1,750

C.

2,000

D.

2,250

Buy Now
Questions 26

When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.

Options:

A.

50

B.

75

C.

100

D.

150

Buy Now
Exam Code: Fire-Inspector-II
Exam Name: 67 - Fire Inspector II Exam
Last Update: Apr 29, 2025
Questions: 87
$57.75  $164.99
$43.75  $124.99
$36.75  $104.99
buy now Fire-Inspector-II