Given: In organic coating processes where Class I liquids are exposed to the air, Class I, Division I electrical installations are required to be outside the immediate vicinity of pumps or equipment.
"Immediate vicinity" means in addition to a vertical distance a zone extending from the vapor liberation point __ ft. horizontally in all directions.
The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not accessible to the public, is __ lb. water capacity.
Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.
Keys necessary for the unlocking of exit doors must be individually identifiable by both sight and touch in which of the following occupancies?
The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.
A required standpipe shall be installed when the progress of construction above the lowest level of fire department access reaches a maximum of __ ft.
Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.
Pressure tests for organic coating process piping shall be conducted for a minimum of:
The minimum working space width for a 66-in. wide electrical equipment panel shall be in
A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds
Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.
How long must records related to this decision be maintained by the code official?
The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.
In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?
What is the occupant load of a 50,000 gross square foot airport terminal concourse?
Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?
Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?
Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with
Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)
When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.